Modicon
™
Momentum
™
automation platform
M1/M1E processor adapters
Introduction
Modicon
™
Momentum
™
M1/M1E processor adapters are based on the Modicon 984
family of products. You can mount these adapters on Modicon Momentum I/O Bases
to provide intelligence to the I/O. The processor adapter can quickly and
independently solve logic, control its own local I/O (discrete or analog), and
communicate to other control entities through one of a number of Modicon
Momentum communication options. The processor adapter can turn an ordinary I/O
Base into a PID controller or high-speed logic solver.
You can create your own controller from a number of different bases, and with other
Modicon Momentum options, network your local logic solvers together into an
intelligent subsystem as part of a larger Modicon application, or into a stand alone,
integrally networked system with local controllers with extended I/O.
Modicon Momentum M1/M1E processor adapters can stand alone, or be mounted
on a single Modicon Momentum I/O Base (with its own extended Modicon
Momentum I/O connected to the I/O Bus Port on 171 CCS 760 00 processor
adapter). It can also be mounted together with one of a variety of Modicon
Momentum Option adapters – providing different network capabilities, a time-of-day
clock, and a battery back-up system. The built-in ash memory is used to store the
executive, allowing for convenient eld upgrades of the operating system. The ash
memory can also be used to back up your applications, creating a local copy of your
program to be loaded back into RAM, thus providing original program le integrity.
On the 171 CCS 780 00 processor adapter, the RS 485 port can be used to connect
to dedicated devices such as an operator interface panel or a marquee, or used in a
master/slave RS 485 network to connect to multiple devices.
The processor adapters can be programmed with Modsoft
™
version 2.5 or greater,
Concept
™
version 2.1 or greater, ProWORX
™
NxT version 2.0 or greater or
ProWORX 32.
The following table describes the specications of the Modicon Momentum M1/M1E
processor adapters.
Specications
Processor adapter RAM Memory Flash Memory Scan Time Modbus Port I/O Bus Port IEC Executive
171 CCS 700 00 64 K 256 K 1 ms/K 1 x RS 232C – –
171 CCS 700 10 64 K 256 K 0.63 ms/K 1 x RS 232C – –
171 CCS 760 00 256 K 256 K 0.63 ms/K 1 x RS 232C 1 x I/O Bus Compatible
171 CCS 780 00 64 K 256 K 1 ms/K 1 x RS 232C
1 x RS 485
– –
171 CCC 760 10 512 K 512 K 1 ms/K 1 x RS 232C 1 x I/O Bus Compatible
171 CCC 780 10 512 K 512 K 1 ms/K 1 x RS 232C
1 x RS 485
– Compatible
171 CCC 960 20 544 K 512 K .3 ms/K 1 x Ethernet 1 x I/O Bus –
171 CCC 960 30 544 K 1 Mb .3 ms/K 1 x Ethernet 1 x I/O Bus Supplied
171 CCC 980 20 544 K 512 K .3 ms/K 1 x RS 485
1 x Ethernet
– –
171 CCC 980 30 544 K 1 Mb .3 ms/K 1 x RS 485
1 x Ethernet
– Supplied
Programming Software for Modicon Momentum
Modicon Momentum processor adapters have a number of PC programming
software options available. You can program your processor adapter via the
Modbus RS 232 serial port, or with an M1E processor via Ethernet network.
If using a Modbus Plus Option adapter in conjunction with a Processor adapter, you
can program via an SA85 card installed in a PC and connected to the same
Modbus Plus network.
For more specic information, see the appropriate Modicon Momentum, ProWORX
or Concept programming software literature and documentation.
Introduction
Specications:
pages 64 to 67
References:
page 68
Vedere la pagina 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 110 111

Commenti su questo manuale

Nessun commento