Modicon
Momentum
automation platform
Option adapters
Introduction
Modicon
Momentum
option adapters, mounted on Modicon Momentum I/O
bases, can be used to enhance the capabilities of the Modicon Momentum
processor adapters that mount on top of the option adapter. These option adapters
allow you to network your local logic solvers together into an intelligent subsystem as
part of a larger Schneider Electric application, or into a stand alone, integrally
networked system with local controllers with extended I/O.
Modicon Momentum option adapter models include:
172 PNN 210 22 - one Modbus Plus
communication port
172 PNN 260 22 - two redundant Modbus Plus communication ports
172 JNN 210 32 - one general-purpose serial communication port, RS 232 or
RS 485 selectable
Each of these option adapters provides an on-board, TOD (Time-Of-Day) clock that
is available to the application residing in the processor adapter. The clock is useful
for the scheduling of events, time-stamping operations and operator interface
requirements. In addition, each option adapter contains a battery-backup system that
maintains the application and its variables in the event of a power outage to the
processor adapter. The option adapter’s convenient side-door access allows for
quick replacement of the single 2/3 AA Lithium battery.
In addition to the TOD clock and battery backup features, the 172 PNN 210 22
adapter allows you to add networking to the intelligent I/O base. Model 172 PNN 260 22
allows you to add redundantly-cabled networking to the I/O base. This opens the
Modicon Momentum product line to a broad spectrum of applications. You can use
the port to connect to other processors, such as:
b
Other Modicon Momentum processor/option adapters
b Other PLCs enabled with Modbus Plus
b Modicon Momentum Modbus Plus communication adapters and I/O bases
b Other third party devices using Modbus Plus to communicate
Model 172 JNN 210 32 allows you to add a second, defacto-industry standard
Modbus port (selectable RS 232/485) to the I/O base. You can use the port to
connect to other processors, such as other Modicon Momentum processor/option
adapters, and to other devices, such as operator interface panels and display
marquees.
Programming software for Modicon Momentum
Modicon Momentum processor adapters have a number of PC programming
software options available. You can program your processor adapter via the
Modbus RS 232 serial port, or if using a Modbus Plus option adapter in conjunction
with a processor adapter, via an SA85 card installed in a PC and connected to the
same Modbus Plus network. For more specic information, see the appropriate
Modicon
Momentum, ProWORX
, and Concept
programming software
documentation.
Introduction
Vedere la pagina 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 110 111

Commenti su questo manuale

Nessun commento

Tripp Lite B125-101-60-WP manuali

Manuali dei proprietari e guide per l'utente per Accessori per TV Tripp Lite B125-101-60-WP.
We fornisce 1 manuali pdf Tripp Lite B125-101-60-WP per scaricare gratuitamente in base al tipo di documento: Manuale Utente






Più prodotti e manuali per Accessori per TV Tripp Lite

Modelli Tipo di Documento
Blue Snagless Cat5e Molded Patch Cable N001-025-BL Manuale Utente   Tripp Lite Blue Snagless Cat5e Molded Patch Cable N001-025-BL User Manual, 3 pagine
N210-007-GY Manuale Utente   Tripp Lite N210-007-GY User Manual, 2 pagine
p774-006 Manuale Utente   Tripp Lite p774-006 User Manual, 2 pagine
Gray Cat6 Gigabit Plenum Snagless Patch Cord N201- Manuale Utente   Tripp Lite Gray Cat6 Gigabit Plenum Snagless Patch Cord N201-050-GY-P User Manual, 2 pagine
Gray Snagless Cat5e Molded Patch Cable N001-050-GY Manuale Utente   Tripp Lite Gray Snagless Cat5e Molded Patch Cable N001-050-GY User Manual, 3 pagine
N002-014-RD Manuale Utente   Tripp Lite N002-014-RD User Manual, 3 pagine
10 GBase CX4 Cable N263-01M Manuale Utente   Tripp Lite 10 GBase CX4 Cable N263-01M User Manual, 2 pagine
Multimode Fiber Optics 2-meter N816-02M Manuale Utente   Tripp Lite Multimode Fiber Optics 2-meter N816-02M User Manual, 2 pagine
p108-000-r Manuale Utente   Tripp Lite p108-000-r User Manual, 2 pagine
P504-100-EZ Manuale Utente   Tripp Lite P504-100-EZ User Manual, 2 pagine
s212-000 Manuale Utente   Tripp Lite s212-000 User Manual, 2 pagine
A102-02M Manuale Utente   Tripp Lite A102-02M User Manual [en] [es] , 2 pagine
p520-006 Manuale Utente   Tripp Lite p520-006 User Manual, 2 pagine
P164-000 Manuale Utente   Tripp Lite P164-000 User Manual, 2 pagine
f007-015 Manuale Utente   Tripp Lite f007-015 User Manual [en] [de] [es] [fr] [it] , 2 pagine
P158-000 Manuale Utente   Tripp Lite P158-000 User Manual [fr] , 3 pagine
Console Converter For SUN B011-000 Manuale Utente   Tripp Lite Console Converter For SUN B011-000 User Manual, 2 pagine
EZA-VGAX-2 Manuale Utente   Tripp Lite EZA-VGAX-2 User Manual, 2 pagine
P608-006 Manuale Utente   Tripp Lite P608-006 User Manual, 2 pagine
Multimode Fiber Optics 3-meter N818-03M Manuale Utente   Tripp Lite Multimode Fiber Optics 3-meter N818-03M User Manual, 2 pagine