The HTML code with the parameters in the window above is as follows:
Minimum EU
Value
Minimum Minimum value, in physical units, of the direct address for
scaling.
Maximum PLC
Value
MaxValue Gross maximum value (without scale) of the direct address in
the PLC.
See Note 3 (See
Notes, p. 162
)
Minimum PLC
Value
MinValue Gross minimum value (without scale) of the direct address in
the PLC.
See Note 3 (See
Notes, p. 162
)
Border Width BorderWidth Width (in pixels) of the border of the graphic object.
Unit ID UnitId Address of the Modbus slave. 1 to 255
Polling rate [ms] Rate Scanning value.
Read Only ReadOnly True = read value, False = read/write value.
Property HTML code Description Limits
<APPLET
codebase="/classes"
archive="mbclient.jar,widgetslite.jar"
code="com.schneiderautomation.factorycast.gateway.sliders.
LiveRotosliderApplet"
width="180" height="160" >
<PARAM name="progressbar" value="true">
<PARAM name="progresscolor" value="#000000">
<PARAM name="debug" value="0">
<PARAM name="BACKGRND" value="LT_GRAY">
<PARAM name="address" value="1">
<PARAM name="datatype" value="REGISTER">
<PARAM name="label" value="label">
<PARAM name="majorTics" value="65535">
<PARAM name="minorTics" value="0">
<PARAM name="precision" value="0">
<PARAM name="degSweep" value="180">
<PARAM name="maximum" value="100">
<PARAM name="minimum" value="0">
<PARAM name="maxValue" value="65535">
<PARAM name="minValue" value="0">
<PARAM name="borderWidth" value="25">
<PARAM name="rate" value="1000">
<PARAM name="readOnly" value="False">
<PARAM name="unitID" value="255">