Schneider Electric TSXETG100 Manuale Utente Pagina 67

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 192
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 66
Services
67
Parameters Description of parameters:
Text Description
Status Indicates the status of the PPP connection:
l inactive if there is no connection,
l server if there is a remote connection,
l client if the TSX ETG 1000 is connected (command or
sending email).
IP remote address IP PPP address of the remote connection. If the PPP
connection is closed IP=0.0.0.0.
IP local address PPP IP address of the local connection (module). If the
PPP connection is closed IP=0.0.0.0.
IP address opened Current IP address opened for the PPP connection (for
client connections only). If the PPP connection is closed
IP=0.0.0.0.
Open connection OK Number of PPP connection opened without error.
Open connection error Number of PPP client connection opened with error (IP
address error, no response from modem, line busy, etc.).
Close connection OK Number of PPP connection closed without error.
Close connection error Number of PPP client connection closed with error (IP
address error, no response from modem, line busy, etc.).
Vedere la pagina 66